Title of article :
Low light conditions modelling for building
integrated photovoltaic (BIPV) systems
Author/Authors :
Ljubisav Stamenic a، نويسنده , , *، نويسنده , , Eric Smiley a، نويسنده , , Karim Karim b، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2004
Abstract :
The low irradiance efficiency of photovoltaic modules is important to the optimization of BIPV systems. When
photovoltaic modules are integrated into a building, architectural design considerations compete with maximizing
photovoltaic energy production. As a result, BIPV arrays are often not facing south and are frequently mounted
vertically. Under these conditions, a greater portion of the total sunlight striking the array is diffuse or at high angles of
incidence. In northern latitudes a significant amount of the total yearly energy is produced at low light levels.
A grid-connected array of BIPV modules integrated into the BCIT Technology Centre building in Burnaby, B.C.
was used for assessing the accuracy of an energy performance model developed for BIPV systems. The BIPV system
uses AC modules and a computerized data acquisition system for monitoring the performance of modules and inverters.
The performance model was developed from analysis of the open circuit voltage, maximum power point voltage and
maximum power point current of the individual modules comprising the BIPV array.
The algorithm for calculating power output of the photovoltaic array is derived from the ideal diode equation using
the single diode model of a photovoltaic cell. An empirically derived parameter modifies the equation. Once the
parameters for different module technologies are established, it is possible to compare their annual performance in a
BIPV system.