Author/Authors :
O. Holck، نويسنده , , J.L.J. Rosenfeld *، نويسنده ,
Abstract :
One construction for a pitched roof is to use tiles on battens, with a liner attached below the battens. The shape of
some types of tiles is such that, at each corner where four tiles overlap, a small gap is formed. At certain positions of the
sun solar radiation can penetrate through these gaps and strike the liner, accelerating its degradation. The purpose of
this study is to estimate the extent and duration of the exposure. A typical gap is modelled in a ray-tracing program
and the size and position of the illuminated area on the liner is calculated for given directions of the light beam relative
to the roof. Analytic expressions for the size of the illuminated area are obtained using a thick slit model. The accuracy
of the model was assessed by some experimental measurements. The exposure over one year of the roof liner was
calculated using the Design Reference Year for Copenhagen, Denmark. Simulations were carried out for a roof tilted
at 25 , 35 or 45 , facing SE, S, SW or W. For the particular roof construction and gap studied, the maximum annual
exposure of a 25mm2 piece of the liner placed 150mm below the gap (corresponding to about 100mm below the base of
the tiles) is about 140kJm 2 to UV-B and 4.2MJ m 2 to UV-A radiation. Variations in tile size and misalignment of
tiles could lead to other gap shapes and sizes, possibly leading to greater exposure. Constructions with the liner placed
closer to the tiles would also lead to greater exposures. However the method developed in this study could form the
basis of a standard method of assessment.
2004 Elsevier Ltd. All rights reserved
Keywords :
building Materials , degradation , Roof liner , ultraviolet radiation