Title of article :
Measurement and simulation of flow rate in a water-in-glass
evacuated tube solar water heater
Author/Authors :
G.L. Morrison a، نويسنده , , *، نويسنده , , I. Budihardjo، نويسنده , , M. Behnia، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2005
Abstract :
This paper evaluates the characteristics of water-in-glass evacuated tube solar water heaters including assessment of
the circulation rate through single ended tubes. A numerical model of the heat transfer and fluid flow inside a singleended
evacuated tube has been developed assuming no interaction between adjacent tubes in the collector array. Flow
measurement using Particle Image Velocimetry (PIV) has been undertaken to validate the numerical model. The experimental
rig consists of a single full-scale tube coupled to a storage tank. A non-dimensional correlation has been developed
of the circulation rate through a single evacuated tube mounted at 45 inclination over a diffuse reflector.
Simulation results show that the natural convection flow rate in the tube is high enough to disturb the tank s stratification
and that the tank temperature strongly affects the circulation flow rate through the tubes. Circumferential heat
distribution was found to be an important parameter influencing the flow structure and circulation rate through the
tube, hence a separate correlation needs to be developed if a concentrating reflector is incorporated into the collector.
2004 Elsevier Ltd. All rights reserved.
Keywords :
natural circulation , Water-in-glass , Evacuated tube
Journal title :
Solar Energy
Journal title :
Solar Energy