Title of article :
Experimental investigation of a two-phase closed
thermosyphon solar water heater
Author/Authors :
Mehmet Esen، نويسنده , , Hikmet Esen، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2005
Abstract :
In this study, experiments were performed to find out how the thermal performance of a two-phase thermosyphon
solar collector was affected by using different refrigerants. Three identical small-scale solar water heating systems, using
refrigerants R-134a, R407C, and R410A, were constructed and tested side-by-side under various environmental and
load conditions. The performance of the system under clear-sky conditions has been investigated with and without
water load. Detailed temperature distributions and cumulative collection efficiencies were determined and presented.
The experimental results were compared to the results found in the literature and they showed good agreement.
2005 Elsevier Ltd. All rights reserved
Keywords :
Phase-change , Heat-pipe solar collector , Refrigerant-charged solar collector , Solar water heating
Journal title :
Solar Energy
Journal title :
Solar Energy