Title of article :
Lead-acid battery capacity in solar home systems—Field tests and experiences in Lundazi, Zambia
Author/Authors :
Mathias Gustavsson، نويسنده , , *، نويسنده , , Daniel Mtonga b، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2005
Pages :
8
From page :
551
To page :
558
Abstract :
Batteries in solar home systems can cause problems and costs for the users and/or operators of the systems. In Zambia the Lundazi Energy Service Company (LESCO) operates 150 solar home systems on a fee for service basis. The aim of the study was to investigate how the capacity of lead-acid flat plate batteries had changed after one year of operation under real conditions. The results indicate that the batteries capacity has been significantly reduced in comparison to new unused batteries of the same type. Changes in battery management and maintenance, along with additional education of customers on correct use of SHS is advised in order to improve the life span of batteries in practical use. 2004 Elsevier Ltd. All rights reserved
Keywords :
Field test , Lead-acid battery performance , Africa , Photovoltaics
Journal title :
Solar Energy
Serial Year :
2005
Journal title :