Title of article :
Optimization of the performance of double-fac¸ades
with integrated photovoltaic panels and motorized blinds
Author/Authors :
Re´mi Charron، نويسنده , , Andreas K. Athienitis، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2006
Abstract :
Double-fac¸ades with integrated photovoltaic panels may be employed to generate electricity, thermal energy and for
daylighting. A theoretical study of double-fac¸ades with integrated photovoltaics (PV) and motorized blinds is presented,
which investigates the effect of various design parameters in order to maximize the conversion of solar radiation
to useful energy. Two configurations of the fac¸ade with a lower section with integrated PV and an upper Vision (viewing)
section with motorized blinds, are examined. A one-dimensional finite-difference thermal model is developed, with
an algorithm that iteratively determines which convective heat transfer coefficient correlation to use for each surface
inside the cavity using expressions that consider system characteristics and temperature distribution. When PV modules
are installed in the middle of the cavity, air flows on both sides, increasing PV section overall (thermal-electric) efficiency
by about 25%, but lowers electricity generation by 21%. Integrating 0.015 m long, 0.002 m wide fins to the PV back
plate leads to a similar increase in efficiency without compromising electricity generation. Placing the blind in the middle
of the cavity increases the Vision section efficiency by 5%. Using this approach to optimize performance can lead to
combined thermal-electric efficiencies of over 60%.
2005 Elsevier Ltd. All rights reserved.
Keywords :
Motorized blinds , Ventilated fac¸ade , Building-integrated photovoltaics
Journal title :
Solar Energy
Journal title :
Solar Energy