Title of article :
Experimental validation of a numerical model
for heat transfer in vacuum glazing
Author/Authors :
Yueping Fang، نويسنده , , *، نويسنده , , Philip C. Eames، نويسنده , , Brian Norton، نويسنده , , Trevor J. Hyde a، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2006
Abstract :
Flat vacuum glazings consisting of a narrow evacuated space between two glass panes separated by an array of small
support pillars have been fabricated. A guarded hot box calorimeter was designed and constructed to measure their heat
transfer coefficients. Experimental measurements of temperatures and rates of heat transfer were found to be in very
good agreement with those predicted using a developed finite element model. A method for determining the heat transfer
coefficient of the evacuated gap has been established and comparisons are made between the measured and predicted
glass surface temperature profiles of the exposed glass area and the heat transfer coefficients of the total glazing system
in order to validated the model.
2005 Elsevier Ltd. All rights reserved
Keywords :
Vacuum glazing , Overall heat transfer coefficient , Guarded hot box calorimeter
Journal title :
Solar Energy
Journal title :
Solar Energy