Title of article :
Heat transfer and friction characteristics of rectangular solar air heater duct using rib-grooved artificial roughness
Author/Authors :
A.R. Jaurker a، نويسنده , , *، نويسنده , , J.S. Saini، نويسنده , , B.K. Gandhi، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2006
Pages :
13
From page :
895
To page :
907
Abstract :
Experimental investigation on the heat transfer and friction characteristics of rib-grooved artificial roughness on one broad heated wall of a large aspect ratio duct shows that Nusselt number can be further enhanced beyond that of ribbed duct while keeping the friction factor enhancement low. The experimental investigation encompassed the Reynolds number range from 3000 to 21,000; relative roughness height 0.0181–0.0363; relative roughness pitch 4.5–10.0, and groove position to pitch ratio 0.3–0.7. The effect of important parameters on the heat transfer coefficient and friction factor has been discussed and the results are compared with the results of ribbed and smooth duct under similar flow conditions. The present investigation clearly demonstrates that the heat transfer coefficient for rib-grooved arrangement is higher than that for the transverse ribs, whereas the friction factor is slightly higher for rib-grooved arrangement as compared to that of rectangular transverse ribs of similar rib height and rib spacing. The conditions for best performance have been determined. Correlations for Nusselt number and friction factor have been developed that predict the values within reasonable limits. 2005 Elsevier Ltd. All rights reserved
Keywords :
Thermo-hydraulic performance , Friction factor , heat transfer coefficient , Solar air heater , Aspect ratio , Artificial roughness
Journal title :
Solar Energy
Serial Year :
2006
Journal title :
Solar Energy
Record number :
939658
Link To Document :
بازگشت