Title of article :
Design and overall energy performance of a ventilated photovoltaic fac¸ade
Author/Authors :
Geun Young Yun، نويسنده , , *، نويسنده , , Mike McEvoy b، نويسنده , , Koen Steemers، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2007
Pages :
12
From page :
383
To page :
394
Abstract :
In this study, a theoretical ventilated photovoltaic (PV) fac¸ade, which functions as a pre-heating device in winter and a natural ventilation system in summer and reduces PV module temperatures, was analysed. The interrelationship between an optimum proportion of transparent window (and an opaque PV module) to the total fac¸ade area, and the variables relevant to the energy performance was assessed. The design parameters under consideration have been categorised according to climate, building characteristics, fac¸ade configurations and PV system elements. One outcome of this investigation is a new index, effectiveness of a PV Fac¸ade (PVEF), that has been developed to evaluate the overall energy performance of a PV fac¸ade with regard to the proportion of useful daylight that may displace the use of electric lighting, and the electricity generated by the PV modules to the heating and cooling energy consumption within a building. In conclusion, the electricity generation and the factors, affecting the ventilation performance of a ventilated PV fac¸ade, have been presented. 2006 Elsevier Ltd. All rights reserved.
Keywords :
Ventilated PV fac¸ade , BiPV , Building energy performance , Effectiveness index of a photovoltaic fac¸ade
Journal title :
Solar Energy
Serial Year :
2007
Journal title :
Solar Energy
Record number :
939774
Link To Document :
بازگشت