Title of article :
Analysis of the thermal performance and comfort conditions
produced by five different passive solar heating strategies in the
United States midwest q
Author/Authors :
Alfredo Ferna´ndez-Gonza´lez *، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2007
Abstract :
This paper presents a summary of the thermal performance of five different passive solar test-cells (Direct Gain, Trombe-wall, Waterwall,
Sunspace, and Roofpond) and a control test-cell during the 2002–2003 heating season in Muncie, Indiana. The results discussed in
this article correspond to the initial phase of a longer study (data were collected from December of 2002 until August of 2004). The project’s
original intent was to identify any barriers to achieving thermal comfort within a space when passive solar heating systems are
employed in severe winter climates with predominant overcast sky conditions. Because of the original intent of this project, the test-cells
were arranged with their smaller facades oriented to the north and south and the longer facades facing east and west. This arrangement
permitted to study temperature differences throughout the day (diurnal operative temperature swings) and also simultaneous temperature
differences throughout the space (a simultaneous comparison of four points instrumented within each cell to detect variations between
the south side and the north side of the test-cells).
The results of this phase of the study show that the Direct Gain strategy had the largest diurnal variations of temperature with an
average operative temperature swing of 7.8 C and a maximum variation during the reported period of 10.3 C. By contrast, the Roofpond
strategy had the smallest diurnal variations of temperature with an average operative temperature swing of 1.2 C and a maximum
variation during the reported period of 1.4 C. In terms of the simultaneous variations in the operative temperature between the south
side and the north side of the test-cells, the Direct Gain strategy showed again the highest variations with an average simultaneous operative
temperature difference between the south and north sides of the test-cell of 2.9 C and a maximum variation during the reported
period of 3.7 C. The Roofpond strategy, on the other hand, had the smallest variations with an average simultaneous operative temperature
difference between the south and north sides of the test-cell of 0.1 C and a maximum variation during the reported period
of 0.2 C. The conclusions of this study demonstrate that diurnal variations of the operative temperature are primarily determined by
the type of passive solar strategy utilized (with direct gain producing the highest temperature swings and the indirect gain strategies producing
the smallest temperature swings) and by the thermal storage capacity of the system (with a higher thermal storage producing a
smaller temperature swing). The simultaneous variations of the operative temperature inside the test-cells during the daytime were mostly
influenced by the type of passive solar strategy utilized (with direct gain producing the highest simultaneous differences in temperature
between the south and north sides of the test-cell and the indirect gain strategies producing the smallest temperature swings).
2006 Elsevier Ltd. All rights reserved
Keywords :
Direct gain , Trombe-wall , Water-wall , Sunspace , Roofpond , Passive solar heating
Journal title :
Solar Energy
Journal title :