• Title of article

    Experimental study of effect of an inner thermal curtain in evaporative cooling system of a cascade greenhouse

  • Author/Authors

    Ashish Shukla، نويسنده , , G.N. Tiwari، نويسنده , , M.S. Sodha، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2008
  • Pages
    12
  • From page
    61
  • To page
    72
  • Abstract
    In this paper experimental study has been carried out in a cascade greenhouse with inner thermal curtain to see the effect of thermal curtain. A thermal model has also been developed to predict the air temperature in a cascade greenhouse. The fan-pad system has been used for evaporative cooling and an inner thermal curtain has been used to divide the greenhouse in two zones. Experiments have been conducted in hot summer conditions at Solar Energy Park, IIT Delhi, New Delhi, India for empty greenhouse. Statistical analysis has been carried out to validate the agreement of experimental observations with predicted values. The values of the root mean square percent deviation and coefficient of correlation has been found out 9.0%, 0.90; 5.0%, 0.95 and 7.0%, 0.97 for April, May and June in case of evaporative cooling without curtain in greenhouse-2. The degree of freedom for the experimental work is 10.0. It is found that the use of evaporative cooling with a thermal curtain reduces the temperature of greenhouse by 5 C and 8 C in the second zone of greenhouse-1 and 2 in comparison to greenhouse without curtain in May. 2007 Elsevier Ltd. All rights reserved.
  • Keywords
    Thermal curtain , Cascade greenhouse , Evaporative cooling
  • Journal title
    Solar Energy
  • Serial Year
    2008
  • Journal title
    Solar Energy
  • Record number