Title of article
Analysis of some available heat transfer coefficients applicable to solar chimney power plant collectors
Author/Authors
Marco Aure´lio dos Santos Bernardes *، نويسنده , , Theodor W. von Backstro¨m *، نويسنده , , Detlev G. Kro¨ger، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2009
Pages
12
From page
264
To page
275
Abstract
A solar chimney power plant consists of a translucent collector which heats the air near the ground and guides it into the base of a
chimney at its centre. The buoyant air rises in the chimney and electricity is generated through one or more turbines in or near the base of
the chimney. Various studies about solar chimney power plant performance have been published. Different calculation approaches with a
variety of considerations have been applied to calculate chimney power plant performance. In particular, two comprehensive studies are
relevant, namely those of (Bernardes, M.A.d. S., Voß, A., Weinrebe, G., 2003. Thermal and technical analyses of solar chimneys. Solar
Energy 75, 511–524; Pretorius, J.P., Kro¨ ger, D.G., 2006b. Solar chimney power plant performance. Transactions of the ASME 128, 302–
311). The paper compares the methods used to calculate the heat fluxes in the collector, and their effects on solar chimney performance.
Reasons for the discrepancies between the predictions of the two models are given. In general the Pretorius model produces higher heat
transfer coefficients and higher heat rate fluxes for both the roof and for the ground surfaces. The two approaches lead to very similar air
temperature rises in the collector and thus, similar produced power.
2008 Elsevier Ltd. All rights reserved.