  • Abstract
    Standard test conditions (STC) of photovoltaic (PV) modules are not representative of field conditions; PV module operating temperature often rises up to 30 °C above STC temperature (25 °C), causing a performance drop of 0.5%/°C for crystalline silicium modules. Normal operating cell temperature (NOCT) provides better estimates of PV module temperature rise. It has nevertheless to be measured; moreover NOCT wind speed conditions do not always fit field conditions. The purpose of this work is to model average PV module temperature at given irradiance levels as a function of meteorological parameters and PV module implementation. Thus, no empirical knowledge of PV module thermal behaviour is required for energy rating basing on irradiation distributions over irradiance levels.
  • Keywords
    Operating temperature , PV module , Site profile