Title of article :
Experimental analysis of thermal performance of flat plate
and evacuated tube solar collectors in stationary standard
and daily conditions
Author/Authors :
E. Zambolin، نويسنده , , D. Del Col، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2010
Abstract :
New comparative tests on two different types of solar collectors are presented in this paper. A standard glazed flat plate collector and
an evacuated tube collector are installed in parallel and tested at the same working conditions; the evacuated collector is a direct flow
through type with external compound parabolic concentrator (CPC) reflectors.
Efficiency in steady-state and quasi-dynamic conditions is measured following the standard EN 12975-2 and it is compared with the
input/output curves measured for the whole day.
The first purpose of the present work is the comparison of results in steady-state and quasi-dynamic test methods both for flat plate
and evacuated tube collectors. Beside this, the objective is to characterize and to compare the daily energy performance of these two types
of collectors. An effective mean for describing and analyzing the daily performance is the so called input/output diagram, in which the
collected solar energy is plotted against the daily incident solar radiation. Test runs have been performed in several conditions to reproduce
different conventional uses (hot water, space heating, solar cooling).
Results are also presented in terms of daily efficiency versus daily average reduced temperature difference: this allows to represent the
comparative characteristics of the two collectors when operating under variable conditions, especially with wide range of incidence
angles.
2010 Elsevier Ltd. All rights reserved
Keywords :
Evacuated tube collector , Efficiency , Daily efficiency , Quasi-dynamic method , Flat plate collector
Journal title :
Solar Energy
Journal title :
Solar Energy