Title of article :
Performance analysis of solar-assisted chemical heat-pump dryer
Author/Authors :
M.I. Fadhel a، نويسنده , , b، نويسنده , , ?، نويسنده , , K. Sopian، نويسنده , , W.R.W. Daud، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2010
Abstract :
A solar-assisted chemical heat-pump dryer has been designed, fabricated and tested. The performance of the system has been studied
under the meteorological conditions of Malaysia. The system consists of four main components: solar collector (evacuated tubes type),
storage tank, solid–gas chemical heat pump unit and dryer chamber. A solid–gas chemical heat pump unit consists of reactor, condenser
and evaporator. The reaction used in this study (CaCl2–NH3). A simulation has been developed, and the predicted results are compared
with those obtained from experiments. The maximum efficiency for evacuated tubes solar collector of 80% has been predicted against the
maximum experiment of 74%. The maximum values of solar fraction from the simulation and experiment are 0.795 and 0.713, respectively,
whereas the coefficient of performance of chemical heat pump (COPh) maximum values 2.2 and 2 are obtained from simulation
and experiments, respectively. The results show that any reduction of energy at condenser as a result of the decrease in solar radiation
will decrease the coefficient of performance of chemical heat pump as well as decrease the efficiency of drying.
2010 Elsevier Ltd. All rights reserved.
Keywords :
Solar fraction , Chemical heat pump , Evacuated tubes collector efficiency , Coefficient of performance , drying
Journal title :
Solar Energy
Journal title :
Solar Energy