Title of article :
An optimized model and test of the China’s first high
temperature parabolic trough solar receiver
Author/Authors :
Guangjie Gong، نويسنده , , Xinyan Huang ?، نويسنده , , Jun Wang، نويسنده , , Menglong Hao، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2010
Abstract :
The vacuum solar receiver is the key component of a parabolic trough solar plant, which plays a prominent role in the gross system
efficiency. Recently, China’s first high temperature vacuum receiver, Sanle-3 HCE, has been developed and produced by Southeast
University and Sanle Electronic Group. Before being utilized in China’s first parabolic trough solar plant, accurately estimating the thermal
properties of this new receiver is important. This paper first establishes and optimizes a 1-D theoretical model at Matlab program to
compute the receiver’s major heat loss through glass envelope, and then systematically analyzes the major influence factors of heat loss.
With the laboratorial steady state test stand, the heat losses of both good vacuum and non-vacuum Sanle-3 receivers were surveyed.
Comparison shows the original 1-D model agrees with the ends covered test while remarkably deviating from end exposed test. For
the purpose of identifying the influence of receiver’s end to total heat loss, an additional 3-D model is built by CFD software to further
investigate the different heat transfer processes of receiver’s end components. The 3-D end model is verified by heating power and IR
temperature distribution images in the test. Combining the optimized 1-D model with the new 3-D end model, the comparison with test
data shows a good accordance. At the same time the heat loss curve and emittance curve of this new receiver are given and compared
with those of several other existing receivers as references.
2010 Elsevier Ltd. All rights reserved.
Keywords :
Parabolic trough , Heat loss model , Thermal tests , Vacuum solar receiver
Journal title :
Solar Energy
Journal title :
Solar Energy