Title of article :
Overall thermal energy and exergy analysis of hybrid photovoltaic thermal array
Author/Authors :
C.S. Rajoria، نويسنده , , Sanjay Agrawal، نويسنده , , G.N. Tiwari، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2012
Pages :
8
From page :
1531
To page :
1538
Abstract :
In this paper, overall thermal energy and exergy analysis has been carried out for different configurations of hybrid photovoltaic thermal (PVT) array. The hybrid PVT array (10.08 m × 2.16 m) is a series and parallel combinations of 36 numbers of PV modules. A one-dimensional transient model for hybrid PVT array has been developed using basic heat transfer equations. On the basis of this transient model, an attempt has been made to select an appropriate hybrid PVT array for different climatic conditions (Bangalore, Jodhpur, New Delhi, and Srinagar) of India. On the basis of high grade energy (i.e. overall exergy gain), case-III has been selected as the most appropriate configuration because overall exergy for case-III is 12.9% higher than case-II. The overall thermal energy and exergy gain for Bangalore is 4.54 × 104 kW h and 2.07 × 104 kW h respectively which is highest in comparison to the other cities.
Keywords :
Energy , Exergy , Hybrid PVT array
Journal title :
Solar Energy
Serial Year :
2012
Journal title :
Solar Energy
Record number :
940997
Link To Document :
بازگشت