Title of article :
Simulated and experimental performance of a heat pipe assisted
solar wall
Author/Authors :
Michael V. Albanese، نويسنده , , Brian S. Robinson، نويسنده , , Ellen G. Brehob، نويسنده , , M. Keith Sharp ?، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2012
Abstract :
Performance was evaluated for a passive solar space heating system utilizing heat pipes to transfer heat through an insulated wall from
an absorber outside the building to a storage tank inside the building. The one-directional, thermal diode heat transfer effect of heat pipes
make them ideal for passive solar applications. Gains by the heat pipe are not lost during cloud cover or periods of low irradiation. Simplified
thermal resistance-based computer models were constructed to simulate the performance of direct gain, indirect gain, and integrated
heat pipe passive solar systems in four different climates. The heat pipe system provided significantly higher solar fractions
than the other passive options in all climates, but was particularly advantageous in cold and cloudy climates. Parametric sensitivity
was evaluated for material and design features related to the collector cover, absorber plate, heat pipe, and water storage tank to determine
a combination providing good thermal performance with diminishing returns for incremental parametric improvements. Important
parameters included a high transmittance glazing, a high performance absorber surface and large thermal storage capacity.
An experimental model of the heat pipe passive solar wall was also tested in a laboratory setting. Experimental variations included
fluid fill levels, addition of insulation on the adiabatic section of the heat pipe, and fins on the outside of the condenser section. Filling the
heat pipe to 120% of the volume of the evaporator section and insulating the adiabatic section achieved a system efficiency of 85%. Addition
of fins on the condenser of the heat pipe did not significantly enhance overall performance.
The computer model was validated by simulating the laboratory experiments and comparing experimental and simulated data. Temperatures
across the system were matched by adjusting the model conductances, which resulted in good agreement with the experiment.
2012 Elsevier Ltd. All rights reserved.
Keywords :
Solar , Heat pipe , Water wall , Solar fraction , Isolated gain , Passive
Journal title :
Solar Energy
Journal title :