Title of article :
Methylene Blue Based Device for Pathogen Reduction in Human Plasma
Author/Authors :
Elikaei، A نويسنده . Virology Laboratory, Research Centre of Iranian Blood Transfusion Organization (IBTO), Tehran, Iran. , , Hosseini ، S M نويسنده Department of Microbiology, Faculty of Biological Science Shahid Beheshti University, GC, Tehran, Iran , , Sharifi، Z نويسنده Virology Laboratory, Research Centre of Iranian Blood Transfusion Organization (IBTO), Tehran, Iran. , , Latifi ، H نويسنده Laser and Plasma Research Institute, Shahid Beheshti University, GC, Tehran, Iran. , , Nikbakht ، H نويسنده Laser and Plasma Research Institute, Shahid Beheshti University, GC, Tehran, Iran. , , Mirshafiee، H نويسنده . Department of Microbiology, Faculty of Biological Science Shahid Beheshti University, GC, Tehran, Iran. , , Asadollahi ، A نويسنده Laser and Plasma Research Institute, Shahid Beheshti University, GC, Tehran, Iran. ,
Issue Information :
فصلنامه با شماره پیاپی 0 سال 2013
Pages :
6
From page :
97
To page :
102
Abstract :
Abstract Background Despite improvement in safety of plasma transfusion some virus transmission still remains a problem. So as World Health Organization (WHO) recommends, many countries developed Pathogen Reduction Technologies (PRT) to inactivate pathogens, in plasma components. The Methylene Blue (MB) based methods is one of the most universal one. The purpose of this research was, produce a device that can inactivate viruses in MB environment. Materials and Methods In this interventional study, each Plasma Sample was illuminated by 70Pieces (PCs) of 1 w red Light Emitting Diodes (LEDs) from one side. These LEDs emit light at central wavelength of 627 nm with 20 nm Full Width at Half Maximum (FWHM). Two model viruses Herpes Simplex Virus (HSV) and Vesicular Stomatitis Virus (VSV) were used and Tissue Culture 50% Infection Dose (TCID50) was used to calculate virus Log reduction. Two concentration of MB and 5 different illumination times were used. Results In 10 µm concentration of MB, HSV had 6.00±0.2 maximum log reduction that obtain after 60 minutes illumination and VSV had 5.50± 0.3 maximum log reduction after 75 minutes illumination. In 1 µM concentration of MB, HSV had 5.20±0.3 maximum log reduction that obtain after 60 minutes illumination and VSV had 4.90± 0.2 maximum log reduction after 75 minutes illumination. Conclusion Results of virus inactivation in this method were similar to other methods (P-value < 0.05 in comparison with Spring method, and P-value > 0.05 in comparison with Theraflex), and it showed this device could inactivate viruses according to WHO recommendation.
Journal title :
Iranian Journal of Pediatric Hematology Oncology
Serial Year :
2013
Journal title :
Iranian Journal of Pediatric Hematology Oncology
Record number :
943325
Link To Document :
بازگشت