• Title of article

    Increasing the loadability of power systems through optimal-local-control actions

  • Author/Authors

    A.C.Z.، de Souza, نويسنده , , L.M.، Honorio, نويسنده , , G.L.، Torres, نويسنده , , G.، Lambert-Torres, نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    -187
  • From page
    188
  • To page
    0
  • Abstract
    This paper deals with the problem of increasing the loadability of power systems which, in turn, can be linked to voltage collapse occurrences. As voltage collapses may be caused by insufficiency of reactive power support, and considering that reactive power can be locally supplied, for instance, by shunt capacitors, this paper addresses the impacts of local control actions on the system loadability. The study is carried out in two steps. First, by using the tangent vector technique, two important areas of the power system are identified: the critical area under the point of view of voltage collapse, and the area most sensitive to active power losses reduction. Second, once these two areas are identified, an optimization technique takes place to optimize the amount of shunt reactive power compensation that should be available in each bus. Numerical results are obtained using the IEEE 14- and 118-bus systems.
  • Keywords
    Genotype , Energy , OBESITY
  • Journal title
    IEEE Transactions on Power Systems
  • Serial Year
    2004
  • Journal title
    IEEE Transactions on Power Systems
  • Record number