• Title of article

    Air-flow patterns and heat fluxes in roof-ventilated multi-span greenhouse with insect-proof screens

  • Author/Authors

    E Shilo، نويسنده , , M Teitel، نويسنده , , Y Mahrer، نويسنده , , T Boulard، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    18
  • From page
    3
  • To page
    20
  • Abstract
    Experiments were performed in a semi-commercial, roof-ventilated, four-span greenhouse with insect-proof screens over its openings, to determine the air-flow patterns, heat fluxes and ventilation rates. The ventilation rate in leeward ventilation increased with wind velocity. A comparison between ventilation rates measured by the tracer gas and energy-balance methods showed good correlation between the two. An indication of the influence of outside wind direction on the ventilation rates and air-flow patterns was observed. The direction of air flow within the greenhouse at plant level was nearly opposite to that of the external wind. Both the mean and turbulent latent heat fluxes through the roof openings were much larger than the sensible heat fluxes. Both the sensible and latent turbulent heat fluxes had high values when the roof openings were opened, and then decayed with time. Their directions at the level of the openings were from the greenhouse towards the outside and at plant level they generally followed the direction of the ambient wind.
  • Keywords
    Greenhouse , Ventilation , Insect-proof screens , Air flow
  • Journal title
    Agricultural and Forest Meteorology
  • Serial Year
    2004
  • Journal title
    Agricultural and Forest Meteorology
  • Record number