Author/Authors :
Marek Lisiewicza، نويسنده , , Robert Heimburgerb، نويسنده , , Jerzy Golimowskia، نويسنده , , U، نويسنده ,
Abstract :
Twenty-seven sites, together with 23 household dust sample sites, representing the home environment, and four
public room dust sample sites, representing working environment mainly offices. have been described in this paper.
The latter were examined to obtain an approximate reference to the home environment data. All the samples were
collected between May and July 1997 by a vacuum-cleaner method, in the city of Warsaw, Poland. The granulometry
of the dusts was determined by their separation into seven fractions in the range 8]500 mm. The concentrations of
Cr, Ni, Cu, Zn, Pb, Br and Fe in the samples were investigated in fractions 8]32, 32]63 and 63]125 mm by the
EDXRF technique. The results showed higher concentrations of these elements in finer fractions 8]32 mm.. The Pb
content in the household dusts was found to be unexpectedly low, ranging from 120 mg g]1 for the 63]125 mm
fraction, up to 210 mg g]1 for the 8]32 mm fraction. Car exhausts could not be determined clearly as the main source
of Pb in the indoor household dusts due to the lack of a Pb]Br intercorrelation. In these dusts, only Cr and Zn
showed a remarkably high content of 90]100 and 1020]1070 mg g]1., respectively. In the household dusts, strong
intercorrelations were present in the three analysed fractions for the metal pairs: Pb]Zn, Pb]Cu, Fe]Cr, and Cu]Cr
weaker.. The working environment rooms showed a higher degree of dustiness by 300%, as compared to the
dwellings. The dusts collected in the working environment rooms showed slightly higher concentrations of Ni and by
50]100% higher concentrations of: Cu, Zn, Pb, Br than the analysed household dusts.
Keywords :
Large city centre , toxic elements , Household dust , Indoor pollution , Vacuum-cleaner dusts