Author/Authors :
F.J. Maringera، نويسنده , , M.G. Akisb، نويسنده , , H. Kainederc، نويسنده , , P. Kindld، نويسنده , , C. Kralike، نويسنده , , H. Lettner، نويسنده , , S. Lueginger g، نويسنده , , E. Nadschl¨ager c، نويسنده , , W. Ringer، نويسنده , , R. Rollef، نويسنده , ,
F. Sch¨onhofere، نويسنده , , S. Sperker، نويسنده , , H. Stadtmannb، نويسنده , , F. Stegerb، نويسنده , , F. Steinh¨ausler ، نويسنده , ,
M. Tschurlovitsi، نويسنده , , R. Winklerf، نويسنده ,
Abstract :
The Austrian radon mitigation joint research project SARAH Žsupported by the Austrian Ministry of Economy
and the Government of Upper Austria., a 2-year follow-up study of the Austrian National Radon Project ŽO¨NRAP.,
was started in 1996. The objectives of the research project were to find simple, cost-effective experimental methods
for the characterisation of the radon situation in dwellings and to evaluate technically and economically the
implementation of state of the art remedial actions for Austrian house types. After an intercomparison exercise of
the assigned radon measuring instruments and detectors five houses were closely examined in regions with elevated
radon levels in the federal state of Upper Austria. In this research work for the first time an extended Blower Door
method Žwhich is conventionally used for determining the tightness of buildings. was successfully applied to radon
diagnosis of buildings. In this paper the methods used for the radon diagnosis, the applied mitigation measures and
the related technical and economical aspects are discussed. In conclusion of the results of this project a common
strategy for solving the radon problem in Austria in the future is presented briefly.
Keywords :
Construction engineering , Natural radioactivity , Radiometric methods , RADON , radiation protection , Building redevelopment , Radon mitigation