Title of article :
Comparison of different sampling techniques for the
evaluation of pesticide spray drift in apple orchards
Author/Authors :
Olivier Brianda، نويسنده , , Florence Bertranda، نويسنده , , Ren´e Seuxa، نويسنده , , Maurice Milleta، نويسنده , , b، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Abstract :
An analytical method using gas chromatography mass spectrometry has been developed for the evaluation of
different sampling techniques to characterise spray drift in a commercial apple orchard. Eleven pesticides were
studied Žfungicides, insecticides and herbicides.. A collection of airborne spray-drift pesticides released from a
low-profile air-blast orchard sprayer was investigated using six types of samplers: Ž1. a Perkin-Elmer low volume
automatic air sampler using with glass tube packed with Supelpak-2; Ž2. a high volume air sampler; Ž3, 4. an impinger
containing cyclohexane that could be preceded by a glass fibre filter; and Ž5, 6. glass cartridges packed with
Supelpak-2 that could be preceded by a glass fibre filter. Retention efficiencies of the different sampling techniques
are compared, and physical forms of the retained pesticides are discussed. These techniques have allowed us to
evaluate pesticide spray-drift in the orchard. Results have shown that the molecules’ properties ŽkH and vapour
pressure. and weather conditions Žtemperature and relative humidity. strongly influence pesticide gas and particles
distribution. However, in the studied orchard, it is difficult to differentiate pesticide spray-drift and post-application
transfers since treatment duration was 2 days.
Keywords :
pesticides , Atmosphere , Orchard , spray drift , Sampling techniques , GC-MS
Journal title :
Science of the Total Environment
Journal title :
Science of the Total Environment