• Title of article

    Thermal analysis of multibarrier interior PM synchronous Machine using lumped parameter model

  • Author/Authors

    T.M.، Jahns, نويسنده , , K.M.، Rahman, نويسنده , , A.M.، EL-Refaie, نويسنده , , N.C.، Harris, نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    7
  • From page
    303
  • To page
    309
  • Abstract
    This paper presents a lumped-parameter thermal model for a multi-barrier interior PM synchronous machine. The model consists of a network of 12 thermal resistances that make it possible to estimate temperatures at 9 critical points inside the machine including the stator end windings, rotor magnets, and the bearings. The details of the model are presented and two machines are analyzed, including a 6 kW 12-pole automotive starter/alternator and a 0.5 kW 4-pole electric water pump machine. The lumped-parameter model results for both machines demonstrate good agreement with results obtained using detailed thermal finite element analysis.
  • Keywords
    Hydrograph
  • Journal title
    IEEE Transactions on Energy Conversion
  • Serial Year
    2004
  • Journal title
    IEEE Transactions on Energy Conversion
  • Record number