Author/Authors :
Minliang Shih، نويسنده , , Wen-Jhy Lee، نويسنده , , Tung-Sheng Shih، نويسنده , , Sheng-Lung Huang b، نويسنده , ,
Guo-Ping Chang-Chien d، نويسنده , , Lin-Chi Wang، نويسنده , , Perng-Jy Tsai، نويسنده , , *، نويسنده ,
Abstract :
This study investigated concentrations, contents and congener profiles of polychlorinated dibenzo-p-dioxins and dibenzofurans
(PCDD/Fs) in the workplaces of a sintering plant. Air samples were collected from the charging zone, the sintering zones of the
sintering grate and the rough roll shredder, and the control room. The charging zone was found to have a higher total suspended
particulate (TSP) but lower PCDD/F concentrations (=4969 Ag nm 3 and 7.61 pg nm 3, respectively) than the sintering zone
(=1422–1448 Ag nm 3 and 19.16–23.17 pg nm 3, respectively). The TSP and PCDD/F concentrations were lowest in the control
room (=98 Ag nm 3 and 1.75 pg nm 3, respectively). However, the above concentrations were within the range of a typical urbanindustrial
area. Quite similar PCDD/F contents were found in particles in the sintering zones and control room (=11.72–14.30 and
15.85 ng g 1, respectively) suggesting that the sintering zone and the control room are very similar. In both charging and sintering
zones, 2,3,4,7,8-PeCDF contributed 40–60% to the total I-TEQ in both the gas phase and particle phase. However, in control room,
both congeners 2,3,4,7,8-PeCDF and 2,3,7,8-TCDD were the main contributors; the later contributed 30% of the total I-TEQ in
gas phase. In control room, the contribution of 2,3,7,8-TCDD to the total PCDD/F concentration in the gas phase greatly exceeded
that in particle phase (=5.5% and 0.8%, respectively). Therefore, solutions must be sought to avoid the transfer of not only the
particle-phase but also the gas-phase PCDD/Fs from the sintering zone to the control room in the future.
Keywords :
PCDD/Fs , Content , Congener profile , Sinter plant