Title of article :
Identifying contemporary and historic sources of soil polychlorinated
dibenzo-p-dioxins and polychlorinated dibenzofurans
in an industrial urban setting
Author/Authors :
Catherine G. Vizard a، نويسنده , , 1، نويسنده , , David L. Rimmer، نويسنده , , ?، نويسنده , , Tanja Pless-Mulloli، نويسنده , , Ian Singleton، نويسنده , , Vivienne S. Air d، نويسنده ,
Issue Information :
هفته نامه با شماره پیاپی سال 2006
Abstract :
A study of soil polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F) concentrations was undertaken
in the vicinity of a municipal solid waste incinerator (MSWI) in Newcastle upon Tyne as a result of concerns raised by local
residents about potential contamination from fugitive and stack emissions. The study area was divided into four sectors (north-east
(NE), south-east (SE), north-west (NW) and south-west (SW)) around the MSWI, and sampling sites were located up to a distance
of 2.25 km. Based on air dispersion modelling, the sampling density was four times greater in the NE (downwind) sector compared
to the SW (upwind) direction, and twice as great in the NW and SE sectors. PCDD/F concentrations found in soil samples ranged
from 6 to 1911 ng I-TEQ/kg DW with a median of 32 ng I-TEQ/kg DW. There was no evidence of elevated concentrations
downwind of the MSWI compared to other directions, nor of any trend in concentration at increasing distance from the MSWI. We
concluded, therefore, that the MSWI fugitive and stack emissions were not a major source of PCDD/F contamination. Analysis of
PCDD/F homologue profiles showed that samples exhibiting furan-dominated and OCDD-dominated profiles and a profile
characteristic of the MSWI ash occurred in distinct clusters. Those samples showing the furan-dominated profile had the largest
PCDD/F concentrations measured as I-TEQ, followed by samples with the incinerator profile, the deposition profile, and the
OCDD-dominated profile. We identified some contamination hotspots located in the SW and SE sampling sectors (upwind of the
MSWI), and potential sources for these hotspots were sought by using historic land use data from maps of the locality dating back
to 1856. We concluded that the cluster of very high concentrations of PCDD/F in soils showing the furan homologue profile were
most likely to have resulted from the disposal of graphite electrode sludges from brine electrolysis carried out at a chemical works
between the 1890s and the 1930s.
Keywords :
urban environment , MSWI emissions , soils , PCDD/F
Journal title :
Science of the Total Environment
Journal title :
Science of the Total Environment