Title of article :
Influence of air humidity and the distance from the source
on negative air ion concentration in indoor air
Author/Authors :
Chih-Cheng Wu، نويسنده , , Grace W.M. Lee، نويسنده , , ?، نويسنده , , Shinhao Yang، نويسنده , , Kuo Pin Yu، نويسنده , , Chia Ling Lou a، نويسنده ,
Issue Information :
هفته نامه با شماره پیاپی سال 2006
Abstract :
Although negative air ionizer is commonly used for indoor air cleaning, few studies examine the concentration gradient of negative
air ion (NAI) in indoor environments. This study investigated the concentration gradient of NAI at various relative humidities and
distances formthe source in indoor air. The NAI was generated by single-electrode negative electric discharge; the discharge was kept at
dark discharge and 30.0 kV. The NAI concentrations were measured at various distances (10−900 cm) from the discharge electrode in
order to identify the distribution of NAI in an indoor environment. The profile of NAI concentration was monitored at different relative
humidities (38.1−73.6%RH) and room temperatures (25.2±1.4 °C). Experimental results indicate that the influence of relative humidity
on the concentration gradient of NAI was complicated. There were four trends for the relationship between NAI concentration and
relative humidity at different distances from the discharge electrode. The changes of NAI concentration with an increase in relative
humidity at different distances were quite steady (10−30 cm), strongly declining (70−360 cm), approaching stability (420−450 cm) and
moderately increasing (560−900 cm). Additionally, the regression analysis of NAI concentrations and distances from the discharge
electrode indicated a logarithmic linear (log-linear) relationship; the distance of log-linear tendency (λ) decreased with an increase in
relative humidity such that the log-linear distance of 38.1%RH was 2.9 times that of 73.6%RH.Moreover, an empirical curve fit based
on this study for the concentration gradient ofNAI generated by negative electric discharge in indoor air was developed for estimating the
NAI concentration at different relative humidities and distances from the source of electric discharge.
Keywords :
Negative air ion , Small air ion , Electric discharge , Indoor air , NAI distribution
Journal title :
Science of the Total Environment
Journal title :
Science of the Total Environment