• Title of article

    Positron Doppler broadening measurements with a LINAC-based slow positron beam

  • Author/Authors

    D. Segers، نويسنده , , J. Paridaens، نويسنده , , T. Van Hoecke، نويسنده , , W. Wagner and C. Dauwe، نويسنده , , L. Dorikens-Vanpraet، نويسنده , , C. Quaeyhaegens، نويسنده , , L.M. Stals، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1995
  • Pages
    6
  • From page
    172
  • To page
    177
  • Abstract
    All the LINAC-based slow positron beams are pulsed. In order to perform Doppler broadening measurements one needs a continuous distribution of the slow positron intensity. This intensity has to be kept as constant as possible. A smearing out of the positron intensity with a Penning trap is described. The first depth profiling results are presented.
  • Journal title
    Applied Surface Science
  • Serial Year
    1995
  • Journal title
    Applied Surface Science
  • Record number

    989940