• Title of article

    Electrical breakdown characteristics of ozonized water treated oxygen-free copper electrodes in a vacuum and their surface conditions

  • Author/Authors

    K. Sekikawa، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    5
  • From page
    695
  • To page
    699
  • Abstract
    The in¯uence of ozonized water treatment on the conditioning effect of a vacuum gap was investigated by applying impulse voltages. With regard to a 30 min treatment, the breakdown ®eld improved from 37.6 MV/m at ®rst voltage application to 261 MV/m after 500 breakdowns. This conditioned breakdown ®eld was lowered to 27.0 MV/m when the electrodes were exposed to air for 3 weeks. Reconditioning, however, was rapidly achieved, and the value was as high as that before being exposed to air. The electrodes exposed to air for 2 months after reconditioning showed similar results to that of those exposed to air for 3 weeks. # 2001 Elsevier Science B.V. All rights reserved
  • Keywords
    Oxygen-free copper , Ozonized water treatment , Breakdown in a vacuum , Conditioning effect
  • Journal title
    Applied Surface Science
  • Serial Year
    2001
  • Journal title
    Applied Surface Science
  • Record number

    996814