Title of article :
Operation of the PF ring vacuum system without an in situ bake-out
Author/Authors :
Y. Hori*، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
4
From page :
724
To page :
727
Abstract :
The vacuum system of the PF ring was commissioned without an in situ bake-out after its upgrading reconstruction in which a great number of vacuum beam ducts were replaced by new or improved ones. The degassing of the ring was decreased suf®ciently by synchrotron-radiation irradiation as expected from previous experiments. The system was successfully commissioned and the required pressure was achieved within a reasonable short period. # 2001 Elsevier Science B.V. All rights reserved.
Keywords :
Light source , synchrotron radiation , Photon stimulated desorption , Bake-out
Journal title :
Applied Surface Science
Serial Year :
2001
Journal title :
Applied Surface Science
Record number :
996820
Link To Document :
بازگشت