Title of article
SIMS depth profile analysis of wear resistant coatings on cutting tools and technical components
Author/Authors
P Willich، نويسنده , , C Steinberg، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
6
From page
263
To page
268
Abstract
For quantitative depth profile analysis of hard and wear resistant coatings (general composition, metal-C:N:O:H:Ar) by secondary ion mass spectrometry (SIMS) the use of Cs+ primary ions in conjunction with the detection of MCs+ (M: element of interest) molecular ions is proposed. As compared with Rutherford backscatterring spectrometry (RBS)/elastic recoil detection (ERD), the accuracy of MCs+-SIMS is about ±10%, irrespective of oxygen concentrations up to 20 at.%. A depth resolution of Δz∼30 nm at a depth of z=2.5 μm is demonstrated on curved (radius 2 mm) surfaces of polished (Ra∼0.005 μm) steel. On rough surfaces (Ra>0.1 μm) the depth resolution significantly degrades (Δz=120 nm at z=2.5 μm) due to effects of shadowing and redeposition. This limits detailed and quantitative studies of interlayers and interfaces. Examples are given for local depth profile analysis on technical components under difficult conditions of surface geometry and topography.
Keywords
SIMS , Quantification , Depth resolution , Wear resistant coatings
Journal title
Applied Surface Science
Serial Year
2001
Journal title
Applied Surface Science
Record number
997239
Link To Document