شماره ركورد
14789
عنوان به زبان ديگر
Ethylenedicysteine Versus Diethylenetriamine Pentaacetic Acid as the Carrier of Technetium Tc 99m in Diuretic Renography for Patients with Upper Urinary Tract Obstruction
پديد آورندگان
Shahrokh Hossein نويسنده , Movahhed Mansour نويسنده , Zargar Shoshtari Mohammad Ali نويسنده , Orafa Amir Mohammad نويسنده , Hekmat Sepideh نويسنده
از صفحه
97
تا صفحه
102
تعداد صفحه
6
چكيده لاتين
Introduction: L,L-ethylenedicysteine (EC) is a new carrier of technetium Tc 99m (99mTc) with a lower affinity to plasma albumin in comparison with diethylenetriamine pentaacetic acid (DTPA). We compared 99mTc-EC scan with 99mTc-DTPA scan in diuretic renography for patients with obstructive uropathy.
Materials and Methods: Thirty-three patients with upper urinary tract obstruction were randomly selected and underwent diuretic renographies by 99mTc-EC and 99mTcDTPA.
The counts of radioisotope per pixel in the target (the kidney) and background tissues as well as the clearance half-life of these two radiopharmaceuticals were measured and compared.
Results: Mean counts of radioisotope per pixel in the target tissue was not different between 99mTc-EC and 99mTc-DTPA scans, but in the background tissue, it was less for 99mTc-EC (P = .003). Target-background ratio was higher for 99mTc-EC scan (3.80 ± 2.11
versus 2.48 ± 1.39; P < .001). Renal clearance half-life of radioisotope was shorter for 99mTc-EC scan than 99mTc-DTPA scan (58.15 ± 15.17 minutes versus 78.65 ± 19.99 minutes; P = .033). The results were similar for uremic patients (with a serum creatinine level > 2mg/dL).
Conclusion: Target-background ratio of radiopharmaceutical uptake rates in diuretic renography was a good indicator of the higher resolution of 99mTc-EC than 99mTc-DTPA scan. We also demonstrated the faster clearance of 99mTc-EC than 99mTc-DTPA. This results in less radiation that is especially useful in children. To our opinion, 99mTc-EC
can better depict the kidneys in comparison with 99mTc-DTPA.
شماره مدرك
1198480
لينک به اين مدرک