پديد آورندگان :
BOUKEZZI LARBI نويسنده , BOUBAKEUR AHMED نويسنده , LAURENT CHRISTIAN نويسنده , LALLOUANI MOUHAMED نويسنده
چكيده لاتين :
The widespread use of cross-linked polyethylene (XLPE) as insulation in the manufacturing
of medium and high voltage cables may be attributed to its outstanding
physical, chemical, mechanical, and electrical properties. However, it is well
known that degradation under service conditions is the major problem in the use of
XLPE as cables insulation. Especially, thermal oxidative degradation produces low
molecular weight and oxygenated products. Several diagnostic measurements have
been used in this study in order to characterize XLPE behaviour under thermal ageing.
Firstly FTIR has been conducted on fresh and aged samples in order to reveal the
effect of thermal ageing on the chemical changes which take place in the XLPE structure.
The main changes are the formation of carbonyl groups (aldehyde, ketone, etc.).
Use of DSC analysis shows the effect of ageing on the melting peak temperature Tmmelting
enthalpy Lי.Hm and lamellar thickness. In the last part we have applied X-ray diffraction
to reveal the variations in percentage of XLPE crystallinity or addition of any
new crystalline phase under thermal ageing. The obtained results showed that thermal
ageing at temperatures above the melting temperature of XLPE has a great effect on
the material structure.