Due to the close relationship between the energy and environmental problems, recovering technology and
optimizing energy consumption have a major role in environment protection by minimization the
atmospheric pollutants such as SOX, COX, NOX. This minimization may decrease the greenhouse effect,
and the ozone layer destruction. On the other hand, optimization of Energy consumption and its
recovering may minimize the water and hot oil consumption at the heat exchangers (reboilers and
condensers) in petroleum distillation columns, specially. The present research has been performed about
the kerosene pre-fractionation unit of one of the countryיs oil refineries. This system includes two
distillation columns with a simple arrangement. Considering that the distillation section consumes a great
deal of energy in the chemical and petroleum industries, hence studying the ways in which we may
decrease this consumption is of great importance. One of these retrofit solutions is the heat integration,
which is going to be presented in this research with a different idea from the other previous methods. This
method makes it possible to add a shell and tube heat exchanger for performing a part of condensation
and evaporation operation which can decrease the heat duties of reboilers and one of the condensers. To
this end , the distillation columns were studied in the process and then the proposed model of columns
arrangement were simulated by heat integration with all input and output streams using the Aspen Plus
software, version 11.1 and the Rad Frac model in this software. The result has showed itself as a save of
14.26%, 10.86% and 14.26% in energy, water and hot oil consumption, respectively. On the other hand