شماره ركورد كنفرانس :
4345
عنوان مقاله :
Investigation of the leakage and maximum stress in plastic concrete cut- off wall with 100 centimeter width instead of clay core in static state on embankment dam’s Raz jargalan
پديدآورندگان :
Sedighian Ahmad Ahmad.sedighian@yahoo.com Khavaran Institude of Higher Education , Ghezel sooflo Abbas Ali Azad Islamic University, mashhad
كليدواژه :
Clay core , ABAQUS , Plastic concrete , The maximum stress , Seepage ,
عنوان كنفرانس :
چهارمين كنفرانس بين المللي رفتار بلند مدت و فن آوري هاي نوسازي سازگار با محيط زيست سدها (LTBD2017)
چكيده فارسي :
The clay core rock fill dams have such a special place in the world. In this kind of dams, the implementation of their core and adjacent filters are placed in the critical path of dam construction. While the coarse grain shells are performable easy and quickly. Considering this fact, the possibility of replacing the clay core with other appropriate sealing material, has been studied. following the sealing plastic concrete dams has been widely used in the world if the use it as sealing element is less considered. Leakage has been the main reason failure in body and foundation and solution is cut-off wall. In this research plastic concrete seal’s wall with 100 centimeter widths will be compered by clay core earth dam. Modeling Raz Jargalan dam was conducted by ABAQUS software in north Khorasan. The result show the maximum stress value reduce in sealing cut-off wall and the stress values of authorized dam are lower and The use of proposed sealing cut-off wall reduce the amount of leakage by 66.6 percent which is significant.