Experimental study of R600a and R436A to replace R134a in a domestic refrigerator and freezer
Author/Authors :
M. Rasti Chem. Eng. Dept., University of Isfahan, Isfahan, I.R. Iran , M.S. Hatamipour Chem. Eng. Dept., University of Isfahan, Isfahan, I.R. Iran , S.F. Aghamiri Chem. Eng. Dept., University of Isfahan, Isfahan, I.R. Iran , M. Tavakoli R&D Dept., Entekhab Industrial Group, Isfahan, I.R. Iran
كليدواژه :
R600a , R436A , R134a , Domestic refrigerator-freezer
سال انتشار :
2011
عنوان كنفرانس :
The 7th International Chemical Engineering Congress & Exhibition (IChEC 2011
زبان مدرك :
انگليسي
چكيده لاتين :
After Montreal protocol R134a and hydrocarbons like propane (R290), n-butane (R600) and ibutane (R600a) are using as refrigerant in most of domestic refrigerators and freezers. But in 1996 Kyoto protocol called for phase out of R134a due to its high GWP1, and replace it with new low ODP2 and GWP refrigerants. Hydrocarbons have zero ODP and 20 GWP. This paper presents feasibility study of using pure and mixture hydrocarbons as alternative refrigerant of R134a in a domestic refrigerator and freezer. A domestic R134a type refrigerator-freezer tested with three different refrigerants namely R4363 , R600a and 105 g R134a. Temperatures at various locations in the domestic refrigerator-freezer and refrigeration cycle and consumed energy recorded. The results showed that energy consumption of R600a and R436A are the same and about 5% is lower than R134a. The effect of freezer and refrigerator air temperatures on energy consumption considered with R436A as a refrigerant. The results showed that R600a and R436A can be considered as a convenient alternative for R134a.
كشور :
ايران
تعداد صفحه 2 :
10
از صفحه :
1
تا صفحه :
10
لينک به اين مدرک :
بازگشت