شماره ركورد كنفرانس :
4670
عنوان مقاله :
Assessing HEP using SPAR-H Method for F B Recovery Instruction
پديدآورندگان :
Nazari Tooraj tnazari@shirazu.ac.ir Department of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran; , Rabiee Ataollah Department of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran , Ramezani Ahmad Department of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran
تعداد صفحه :
7
كليدواژه :
VVER , 1000 , TLFW , Feed Bleed , SPAR , H method , RELAP5
سال انتشار :
1397
عنوان كنفرانس :
پنجمين كنفرانس بين المللي قابليت اطمينان و ايمني
زبان مدرك :
انگليسي
چكيده فارسي :
The primary side Feed Bleed (F B) recovery strategy is the last plan to avoid core damage in the event of loss of heat removal from the secondary side. In the context of accident management, besides multiple safety systems’ well-functioning, human factor has a significant role in avoiding the extreme scenarios. In this research, it is tried to quantify Human Error Probability (HEP) of operators’ interference to initiate F B recovery procedure when the Total Loss of Feedwater (TLFW) accident occurs in a typical VVER-1000 Nuclear Power Plant (NPP) via Standardized Plant Analysis Risk-Human Reliability Analysis (SPAR-H) method. Among those factors that affect human performance is the available time for the operators’ late interference in order to reestablish natural circulation to remove the residual heat after the reactor scrammed, which is computed using the best estimate code RELAP5 Mod 3.2. It is revealed that the diagnosis and the action HEPs of the operators are highly dependent, and the combined HEP value is too risky with an unacceptable amount of uncertainty. It is concluded that the accident management procedure must be redesigned to eliminate diagnosis and action dependency.
كشور :
ايران
لينک به اين مدرک :
بازگشت