• Author/Authors

    I. Kaya and D. P. Atherton، نويسنده ,

  • DocumentNumber
    1384530
  • Title Of Article

    Obtaining controller parameters for a new PI-PD Smith predictor using autotuning

  • شماره ركورد
    11241
  • Latin Abstract
    The paper extends a recent work on a modified PI-PD Smith predictor, which leads to significant improvements in the control of processes with large time constants or an integrator or unstable plant transfer functions plus long dead-time for reference inputs and disturbance rejections. Processes with high orders or long time delays are modelled with lower order plant transfer functions with longer time delays. The PI-PD controller is designed so that the delay free part of the system output will follow the response of a first order plant or second order plant, where it is appropriate, assuming a perfect matching between the actual plant and model in both the dynamics and time delay. The provided simple tuning formulae have physically meaningful parameters. Plant model transfer functions and controller settings are identified based on exact analysis from a single relay feedback test using the peak amplitude and frequency of the process output. Examples are given to illustrate the simplicity and superiority of the proposed method compared with some existing ones.
  • From Page
    465
  • NaturalLanguageKeyword
    Smith predictor , Identification , PID controllers , Disturbance rejection
  • JournalTitle
    Studia Iranica
  • To Page
    472
  • To Page
    472