• Author/Authors

    Ari Ingimundarson، نويسنده , , Tore H?gglund، نويسنده ,

  • DocumentNumber
    1384495
  • Title Of Article

    Performance comparison between PID and dead-time compensating controllers

  • شماره ركورد
    11459
  • Latin Abstract
    This paper is intended to answer the question: ‘‘When can a simple dead-time compensator be expected to perform better than a PID?ʹʹ. The performance criterion used is the integrated absolute error (IAE). It is compared for PI and PID controllers and a simple dead-time compensator (DTC) when a step load disturbance is applied at the plant input. Both stable and integrating processes are considered. For a fair comparison the controllers should provide equal robustness in some sense. Here, as a measure of robustness, the H∞ norm of the sum of the absolute values of the sensitivity function and the complementary sensitivity function is used. Performance of the DTCʹs is given also as a function of dead-time margin (DM).
  • From Page
    887
  • NaturalLanguageKeyword
    performance comparison , PID control , Dead-time compensators
  • JournalTitle
    Studia Iranica
  • To Page
    895
  • To Page
    895