Author/Authors :
yakar, gülay pamukkale üniversitesi - mühendislik fakültesi - makine mühendisliği bölümü, Denizli, Türkiye
Title Of Article :
Experimental investigation of effectiveness of heating tube with conical baffles
شماره ركورد :
40941
Abstract :
In this paper, effectiveness of heated tube with conical baffles was studied experimentally as a function of various inclination angles. By using inclined conical baffles vortex of the flow was increased thereby giving rise to heat transfer and the best inclination angle was determined. Experiments were performed for three different inclination angles (45°, 60° ve 80°). Water as hot fluid and air as cold fluid were used as working fluids in the experiments. Water temperature was fixed as 65 °C. Air flow velocities were taken at 8 distinct levels between 2-20 m/s. The results indicated that for NTU 1, 45° and 80° were more effective compared to 60°. In addition for NTU 1, all three angles were found to be similarly effective.
From Page :
378
NaturalLanguageKeyword :
Effectiveness , Conical baffle , Inclination angle
JournalTitle :
Pamukkale University Journal Of Engineering Sciences
To Page :
382
Link To Document :
بازگشت