• DocumentCode
    1000700
  • Title

    Calculation of Single-Phase Series Motor Control Characteristics

  • Author

    Moore, H.G. ; Axtell, C.J.

  • Author_Institution
    General Electric Company, Erie, Pa.
  • Volume
    52
  • Issue
    2
  • fYear
    1933
  • fDate
    6/1/1933 12:00:00 AM
  • Firstpage
    356
  • Lastpage
    358
  • Abstract
    This paper describes a simple method of plotting acceleration curves by resolving the reactance and resistance of the transformer, reactive coil, and wiring into a single effective reactance and effective resistance for each open-circuit transformer secondary voltage. By the use of these factors and the motor characteristics simple calculations can be made to determine with any given motor voltage and load the required open-circuit voltage of the transformer. Any errors introduced by the use of the approximate values of effective reactance and resistance are of very minor value and do not appreciably affect the final results.
  • Keywords
    Acceleration; Circuits; Coils; Contact resistance; Impedance; Motor drives; Rail transportation; Wiring;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Transactions of the
  • Publisher
    ieee
  • ISSN
    0096-3860
  • Type

    jour

  • DOI
    10.1109/T-AIEE.1933.5056311
  • Filename
    5056311