• DocumentCode
    1000787
  • Title

    Measurements of off-axis energy deposition form 100 MeV electrons traversing water and liquid nitrogen

  • Author

    Maruyama, X.K. ; Buskirk, F.R. ; Neighbours, J.R. ; Fizpatrick, R.D. ; Cromar, P.F. ; Mack, J.M.

  • Author_Institution
    US Naval Postgraduate Sch., Monterey, CA, USA
  • Volume
    35
  • Issue
    6
  • fYear
    1988
  • fDate
    12/1/1988 12:00:00 AM
  • Firstpage
    1278
  • Lastpage
    1281
  • Abstract
    Using the US Naval Postgraduate School 100 MeV linear electron accelerator, the authors measured the dose delivered in water and liquid nitrogen near the axis of an electron beam with calcium fluoride thermoluminescent dosimeters. The measurements show that calculations can predict dose near an electron beam. Calculations were done with CYLTRAN, a Monte Carlo electron/photon transport code, but, as the physical basis for this and other members of the Integrated Tiger Series is the same, the use of other codes is not expected to provide significant differences. The uncertainties in the physical arrangement of dosimeters do not readily lend themselves to precision measurements, but data and calculation agree adequately over many orders of magnitude. A prescription is presented to extend results obtained in one medium (H 2O or LN2) to another (air), where geometry considerations make experiments difficult
  • Keywords
    dosimetry; electron beam effects; nitrogen; water; 100 MeV; CYLTRAN; CaF2 thermoluminescent dosimeters; Integrated Tiger Series; Monte Carlo electron/photon transport code; delivered dose; electron beam; liquid N2; off-axis energy deposition; water; Aluminum; Containers; Electron beams; Energy measurement; Length measurement; Monitoring; Nitrogen; Radiation detectors; Scattering; Solids;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.25452
  • Filename
    25452