• DocumentCode
    1001127
  • Title

    Unity-gain frequency-independent precision phase-shifter

  • Author

    Chambers, R.G.

  • Author_Institution
    Central Electricity Generating Board, Scientific Services Department, Harrogate, UK
  • Volume
    20
  • Issue
    4
  • fYear
    1984
  • Firstpage
    151
  • Lastpage
    152
  • Abstract
    The letter describes an operational amplifier circuit which gives a constant (±0.1°) phase shift and a constant (±0.1%) unity gain to a sinusoidal signal, over a frequency band of range ±2%. The circuit incorporates two standard phase-shifters with different characteristics, deployed so that their phase errors mutually cancel as the frequency deviates from its central value. The device has been used as a phase-shifter in a precise negative phase sequence current measurement circuit in a power system.
  • Keywords
    electric current measurement; operational amplifiers; phase shifters; frequency-independent precision phase-shifter; negative phase sequence current measurement circuit; operational amplifier circuit; phase errors; unity gain;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19840101
  • Filename
    4249713