DocumentCode :
1001248
Title :
Weissfloch transformer for antenna impedance measurements
Author :
Toker, Canan
Author_Institution :
Middle East Technical University, Ankara, Turkey
Volume :
21
Issue :
4
fYear :
1973
fDate :
7/1/1973 12:00:00 AM
Firstpage :
585
Lastpage :
588
Abstract :
An antenna impedance measurement technique based on the Weissfloch transformer theorem is described. In this method the antenna impedance is compared to a normalizing load whose value can be determined to a high degree of precision. The method provides a perfect transformer action between the antenna terminals and a point in the input transmission line, with the known transformer ratio. Baluns and other auxiliary antenna components are treated as a discontinuity and their intervening effects in the measurement accuracy are eliminated.
Keywords :
Antenna measurements; Impedance measurement; Antenna accessories; Antenna measurements; Antenna theory; Impedance matching; Impedance measurement; Loaded antennas; Transmission line antennas; Transmission line discontinuities; Transmission line measurements; Transmission line theory;
fLanguage :
English
Journal_Title :
Antennas and Propagation, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-926X
Type :
jour
DOI :
10.1109/TAP.1973.1140545
Filename :
1140545
Link To Document :
بازگشت