DocumentCode
1004827
Title
Simplified calibration equations for computer-corrected network analyser using matched-impedance normalisation
Author
Tenen, O.
Author_Institution
Telecom Australia, Planning HQ, Melbourne, Australia
Volume
19
Issue
9
fYear
1983
Firstpage
314
Lastpage
316
Abstract
Explicit expressions are presented for a bidirectional computer-corrected network analyser using matched-impedance normalisation. It is shown that this procedure simplifies the equations and considerably reduces the number of error terms possible in measurements with network analysers. In addition errors due to source switching, if they do arise, can be rigorously accounted for. However, this requires an extended calibration procedure with a two-port network standard.
Keywords
calibration; computerised instrumentation; impedance matching; measurement errors; microwave measurement; network analysers; CAD; CCNA; bidirectional network analyser; calibration; computer-corrected network analyser; error terms reduction; matched-impedance normalisation; microwave techniques; source switching errors;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:19830217
Filename
4250780
Link To Document