DocumentCode
1006369
Title
Breakdown Curve for Solid Insulation
Author
Montsinger, V.M.
Author_Institution
General Electric Co. Pittsfield, Mass
Volume
54
Issue
12
fYear
1935
Firstpage
1300
Lastpage
1301
Abstract
A volt-time breakdown curve for solid insulation, constructed from test data obtained with the use of square edged electrodes, is given in this paper, considerably extending the range of information available on this subject.
Keywords
Breakdown voltage; Dielectric breakdown; Dielectrics and electrical insulation; Electric breakdown; Electrodes; Insulation testing; Oil insulation; Power transformer insulation;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Transactions of the
Publisher
ieee
ISSN
0096-3860
Type
jour
DOI
10.1109/T-AIEE.1935.5056923
Filename
5056923