DocumentCode
1006449
Title
Amplitude-locked loop analysis for calibration applications
Author
Charles, C.T. ; Allstot, D.J.
Author_Institution
Dept. of Electr. Eng., Univ. of Washington, Seattle, WA, USA
Volume
42
Issue
11
fYear
2006
fDate
5/25/2006 12:00:00 AM
Firstpage
614
Lastpage
615
Abstract
A linear analysis of an ALL, as it would be used in an amplitude calibration, is presented. The impact of different loop filter choices is considered, for steady-state error and loop dynamics as well as for disturbances in the input amplitude and peak detector ripple. It is shown that in most applications a loop filter with an integrator is desirable.
Keywords
calibration; circuit feedback; phase locked loops; amplitude calibration; amplitude-locked loop analysis; integrator; loop dynamics; loop filter; steady-state error;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/iel:200601008
Filename
1648592
Link To Document