Title :
On the nonexistence of "Ampere tension" in electric conductors
Author :
Carpenter, Keith ; Graneau, P.
Author_Institution :
University of Missouri-Rolla, Rolla, MO
fDate :
11/1/1984 12:00:00 AM
Abstract :
The "Ampere tension" described by Graneau in a recent paper is due to errors in calculation and interpretation of the Ampere force law and is not a real phenomenon.
Keywords :
Circuit analysis; Circuit faults; Conductors; Current density; Diodes; Finite difference methods; Helium; Lorentz covariance; Magnetic fields; Wire;
Journal_Title :
Magnetics, IEEE Transactions on
DOI :
10.1109/TMAG.1984.1063571