Abstract :
Armature resistance of synchronous machines, although usually disregarded when making torque-angle and excitation calculations, must be taken into account when making an accurate analysis. Values of armature resistance obtained in a series of tests are presented in this paper, which is a companion paper to ``Test Values of Armature Leakage Reactance´´ in this issue, pages 700-5. Discussion of test methods, the effect of pole form on losses, and the use of effective armature resistance in determining the vector diagram of the machine are included herein.
Keywords :
Alternators; Density estimation robust algorithm; Induction motors; Steady-state; Synchronous machines; Synchronous motors;
fLanguage :
English
Journal_Title :
American Institute of Electrical Engineers, Transactions of the
Publisher :
ieee
ISSN :
0096-3860
Type :
jour
DOI :
10.1109/T-AIEE.1935.5057063